A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä
Day-to-Day Variability and Year-to-Year Reproducibility of Accelerometer-Measured Free-Living Sit-to-Stand Transitions Volume and Intensity among Community-Dwelling Older Adults (2021)
Löppönen, A., Karavirta, L., Portegijs, E., Koivunen, K., Rantanen, T., Finni, T., Delecluse, C., Van Roie, E., & Rantalainen, T. (2021). Day-to-Day Variability and Year-to-Year Reproducibility of Accelerometer-Measured Free-Living Sit-to-Stand Transitions Volume and Intensity among Community-Dwelling Older Adults. Sensors, 21(18), Article 6068. https://doi.org/10.3390/s21186068
JYU-tekijät tai -toimittajat
Julkaisun tiedot
Julkaisun kaikki tekijät tai toimittajat: Löppönen, Antti; Karavirta, Laura; Portegijs, Erja; Koivunen, Kaisa; Rantanen, Taina; Finni, Taija; Delecluse, Christophe; Van Roie, Evelien; Rantalainen, Timo
Lehti tai sarja: Sensors
eISSN: 1424-8220
Julkaisuvuosi: 2021
Ilmestymispäivä: 10.09.2021
Volyymi: 21
Lehden numero: 18
Artikkelinumero: 6068
Kustantaja: MDPI AG
Julkaisumaa: Sveitsi
Julkaisun kieli: englanti
DOI: https://doi.org/10.3390/s21186068
Julkaisun avoin saatavuus: Avoimesti saatavilla
Julkaisukanavan avoin saatavuus: Kokonaan avoin julkaisukanava
Julkaisu on rinnakkaistallennettu (JYX): https://jyx.jyu.fi/handle/123456789/77813
Tiivistelmä
(1) Background: The purpose of this study was to evaluate the day-to-day variability and year-to-year reproducibility of an accelerometer-based algorithm for sit-to-stand (STS) transitions in a free-living environment among community-dwelling older adults. (2) Methods: Free-living thigh-worn accelerometry was recorded for three to seven days in 86 (women n = 55) community-dwelling older adults, on two occasions separated by one year, to evaluate the long-term consistency of free-living behavior. (3) Results: Year-to-year intraclass correlation coefficients (ICC) for the number of STS transitions were 0.79 (95% confidence interval, 0.70–0.86, p < 0.001), for mean angular velocity—0.81 (95% ci, 0.72–0.87, p < 0.001), and maximal angular velocity—0.73 (95% ci, 0.61–0.82, p < 0.001), respectively. Day-to-day ICCs were 0.63–0.72 for number of STS transitions (95% ci, 0.49–0.81, p < 0.001) and for mean angular velocity—0.75–0.80 (95% ci, 0.64–0.87, p < 0.001). Minimum detectable change (MDC) was 20.1 transitions/day for volume, 9.7°/s for mean intensity, and 31.7°/s for maximal intensity. (4) Conclusions: The volume and intensity of STS transitions monitored by a thigh-worn accelerometer and a sit-to-stand transitions algorithm are reproducible from day to day and year to year. The accelerometer can be used to reliably study STS transitions in free-living environments, which could add value to identifying individuals at increased risk for functional disability.
YSO-asiasanat: ikääntyneet; fyysinen aktiivisuus; liikuntarajoitteet; mittausmenetelmät
Vapaat asiasanat: test-retest; mobility limitation; chair rise
Liittyvät organisaatiot
Hankkeet, joissa julkaisu on tehty
- Active ageing - resilience and external support as modifiers of the disablement outcome
- Rantanen, Taina
- Euroopan komissio
- Are older people becoming younger?
Cohort differences in perceived age and functional capacity among 75- and 80-year-old people assessed 28 years apart (The Evergreen 2)- Rantanen, Taina
- Suomen Akatemia
- Kehollinen liikkuminen ja kyky säilyttää elämänlaatu ikääntymisen yhteydessä
- Rantalainen, Timo
- Suomen Akatemia
- Kehollinen liikkuminen ja kyky säilyttää elämänlaatu ikääntymisen yhteydessä (tutkimuskulut)
- Rantalainen, Timo
- Suomen Akatemia
OKM-raportointi: Kyllä
Raportointivuosi: 2021
JUFO-taso: 1