A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä
Aerobic Capacity Determines Habitual Walking Acceleration, Not Electromyography-Indicated Relative Effort (2022)
Pesola, A. J., Rantalainen, T., Gao, Y., & Finni, T. (2022). Aerobic Capacity Determines Habitual Walking Acceleration, Not Electromyography-Indicated Relative Effort. Journal for the Measurement of Physical Behaviour, 5(1), 32-41. https://doi.org/10.1123/jmpb.2021-0018
JYU-tekijät tai -toimittajat
Julkaisun tiedot
Julkaisun kaikki tekijät tai toimittajat: Pesola, Arto J.; Rantalainen, Timo; Gao, Ying; Finni, Taija
Lehti tai sarja: Journal for the Measurement of Physical Behaviour
ISSN: 2575-6605
eISSN: 2575-6613
Julkaisuvuosi: 2022
Volyymi: 5
Lehden numero: 1
Artikkelin sivunumerot: 32-41
Kustantaja: Human Kinetics Publishers
Julkaisumaa: Yhdysvallat (USA)
Julkaisun kieli: englanti
DOI: https://doi.org/10.1123/jmpb.2021-0018
Julkaisun avoin saatavuus: Avoimesti saatavilla
Julkaisukanavan avoin saatavuus: Osittain avoin julkaisukanava
Tiivistelmä
Methods: Forty volunteers (19 women; age 49.3 ± 17.1 years, body mass index 24.0 ± 2.6 kg/m2; peak oxygen uptake 40.3 ± 12.5 ml/kg/min) wore EMG-shorts and a hip-worn accelerometer simultaneously for 11.6 ± 2.2 hr on 1.7 ± 1.1 days. Continuous gait bouts of at least 5-min duration were identified based on acceleration mean amplitude deviation (MAD, in milli gravitational acceleration, mg) and mean EMG amplitude, with EMG normalized to maximal isometric knee extension and flexion (EMG, in percentage of maximal voluntary contraction EMG). Peak oxygen uptake was measured on a treadmill and maximal strength in isometric leg press (leg press max). MAD and EMG were compared between age- and sex-specific fitness groups (low-average, good, and excellent) and in linear models.
Results: During habitual walking bouts (4.1 ± 4.1 bouts/day, 0.9 ± 1.0 min/bout), the low-average fit participants had an approximately 28% lower MAD (245 ± 64.3 mg) compared with both good fit and excellent fit participants (313 ± 68.1 mg, p < .05), but EMG was the same (13.1% ± 8.42% maximal voluntary contraction EMG, p = .10). Absolute, relative to body mass, and relative to skeletal muscle mass peak oxygen uptake (but not leg press max) was positively associated with MAD independent of age and sex (p < .01), but there were no associations with EMG.
Conclusions: People with low-average aerobic capacity habitually walk with a lower accelerometer-measured absolute intensity, but the physiological stimulus for lower-extremity muscles is similar to those with excellent aerobic capacity. This should be considered when measuring and prescribing walking for health.
YSO-asiasanat: kävely; askeleet; fyysinen aktiivisuus; lihasaktiivisuus; aerobinen suorituskyky; askelmittarit
Vapaat asiasanat: gait; accelerometer; muscle activity; wearable; aerobic fitness; physical activity
Liittyvät organisaatiot
OKM-raportointi: Kyllä
Raportointivuosi: 2022
Alustava JUFO-taso: 1