A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä
RAPTOR : A new collinear laser ionization spectroscopy and laser-radiofrequency double-resonance experiment at the IGISOL facility (2023)
Kujanpää, S., Raggio, A., de Groote, R. P., Athanasakis-Kaklamanakis, M., Block, M., Candiello, A., Gins, W., Koszorús, Á., Moore, I. D., Reponen, M., & Warbinek, J. (2023). RAPTOR : A new collinear laser ionization spectroscopy and laser-radiofrequency double-resonance experiment at the IGISOL facility. Nuclear Instruments and Methods in Physics Research. Section B : Beam Interactions with Materials and Atoms, 541, 388-391. https://doi.org/10.1016/j.nimb.2023.05.014
JYU-tekijät tai -toimittajat
Julkaisun tiedot
Julkaisun kaikki tekijät tai toimittajat: Kujanpää, S.; Raggio, A.; de Groote, R. P.; Athanasakis-Kaklamanakis, M.; Block, M.; Candiello, A.; Gins, W.; Koszorús, Á.; Moore, I. D.; Reponen, M.; et al.
Lehti tai sarja: Nuclear Instruments and Methods in Physics Research. Section B : Beam Interactions with Materials and Atoms
ISSN: 0168-583X
eISSN: 1872-9584
Julkaisuvuosi: 2023
Ilmestymispäivä: 06.06.2023
Volyymi: 541
Artikkelin sivunumerot: 388-391
Kustantaja: Elsevier BV
Julkaisumaa: Alankomaat
Julkaisun kieli: englanti
DOI: https://doi.org/10.1016/j.nimb.2023.05.014
Julkaisun avoin saatavuus: Avoimesti saatavilla
Julkaisukanavan avoin saatavuus: Osittain avoin julkaisukanava
Julkaisu on rinnakkaistallennettu (JYX): https://jyx.jyu.fi/handle/123456789/87607
Rinnakkaistallenteen verkko-osoite (pre-print): https://arxiv.org/abs/2302.14637
Tiivistelmä
RAPTOR, Resonance ionization spectroscopy And Purification Traps for Optimized spectRoscopy, is a new collinear resonance ionization spectroscopy device constructed at the Ion Guide Isotope Separator On-Line (IGISOL) facility at the University of Jyväskylä, Finland. By operating at beam energies of under 10 keV, the footprint of the experiment is reduced compared to more traditional collinear laser spectroscopy beamlines. In addition, RAPTOR is coupled to the JYFLTRAP Penning trap mass spectrometer, opening a window to laser-assisted nuclear-state selective purification, serving not only the mass measurement program, but also supporting post-trap decay spectroscopy experiments. Finally, the low-energy ion beams used for RAPTOR will enable high-precision laser-radiofrequency double-resonance experiments, resulting in spectroscopy with linewidths below 1 MHz. In this contribution, the technical layout of RAPTOR and a selection of ion-beam optical simulations for the device are presented, along with a discussion of the current status of the commissioning experiments.
YSO-asiasanat: ydinfysiikka; tutkimuslaitteet
Vapaat asiasanat: collinear laser spectroscopy; IGISOL; exotic nuclei; laser resonance ionization
Liittyvät organisaatiot
OKM-raportointi: Kyllä
Raportointivuosi: 2023
Alustava JUFO-taso: 2