B3 Vertaisarvioimaton artikkeli konferenssijulkaisussa
Benchmark evaluation of a single frequency continuous wave OPO seeded pulsed dye amplifier for high-resolution laser spectroscopy (2023)


Urquiza-González, M., Au, M., Bernerd, C., Bissell, M. L., van den Borne, B., Chrysalidis, K., Cocolios, T. E., Fedosseev, V., Flanagan, K. T., Garcia Ruiz, R. F., Geldhof, S., de Groote, R. P., Koszorús, Á., Hanstorp, D., Heines, M., Heinke, R., Hens, K., Khwairakpam, O. S., Kujanpää, S., . . . Yang, X. F. (2023). Benchmark evaluation of a single frequency continuous wave OPO seeded pulsed dye amplifier for high-resolution laser spectroscopy. In W. A. Clarkson, & R. K. Shori (Eds.), Solid State Lasers XXXII : Technology and Devices (Article 123990M). SPIE. Proceedings of SPIE : the International Society for Optical Engineering, 12399. https://doi.org/10.1117/12.2646665


JYU-tekijät tai -toimittajat


Julkaisun tiedot

Julkaisun kaikki tekijät tai toimittajatUrquiza-González, M.; Au, M.; Bernerd, C.; Bissell, M. L.; van den Borne, B.; Chrysalidis, K.; Cocolios, Thomas E.; Fedosseev, V.; Flanagan, K. T.; Garcia Ruiz, R. F.; et al.

EmojulkaisuSolid State Lasers XXXII : Technology and Devices

Emojulkaisun toimittajatClarkson, W. Andrew; Shori, Ramesh K.

Konferenssin paikka ja aikaSan Francisco, United States31.1.-1.2.2023

ISBN978-1-5106-5903-2

eISBN978-1-5106-5904-9

Lehti tai sarjaProceedings of SPIE : the International Society for Optical Engineering

ISSN0277-786X

eISSN1996-756X

Julkaisuvuosi2023

Ilmestymispäivä08.03.2023

Sarjan numero12399

Artikkelinumero123990M

KustantajaSPIE

JulkaisumaaYhdysvallat (USA)

Julkaisun kielienglanti

DOIhttps://doi.org/10.1117/12.2646665

Julkaisun avoin saatavuusEi avoin

Julkaisukanavan avoin saatavuus


Tiivistelmä

The study of the atomic spectrum via resonant laser excitation provides access to underlying effects caused by the nuclear structure, which is of special interest in short-lived radioisotopes produced at Isotope Separator On-Line (ISOL) facilities. Current implementations of resonant laser ionization techniques often limit the extraction of the nuclear observables due to the low spectral resolution of the pulsed laser systems deployed. Several high-resolution spectroscopy techniques demand spectral widths in the order of hundreds of MHz and below. A proven solution to reduce this linewidth is the pulsed amplification of a narrow-band continuous wave (cw) laser. This work presents the demonstration of a pulsed dye amplifier seeded by a commercially available cw Optical Parametric Oscillator (OPO). The performance of this system was compared with competing setups using a cw dye laser seed source as well as a frequency mixing technique using a combination of an injection-locked titanium:sapphire (Ti:Sa) and a Nd:YVO4 laser. Spectral bandwidths of the systems were measured using a high finesse Fabry-Perot Interferometer, resulting in comparable optical linewidths between 140 to 156 MHz at a wavelength of 328 nm for the different laser setups. Suitability for on-line experiments was validated by performing high-resolution spectroscopy of radioactive silver isotopes in the Collinear Resonance Ionization Spectroscopy (CRIS) experiment at the Isotope Separator On-Line Device (ISOLDE), at the European Organization for Nuclear Research (CERN). The quality of the hyperfine spectra was similar for the dye and the OPO seed and the deduced hyperfine splitting was in good agreement with literature, while the frequency mixing technique exhibited less precise results attributed to the frequency instabilities and mode-hops of the single-mode Nd:YVO4 laser.


YSO-asiasanatlasertekniikkaspektroskopiaydinfysiikka

Vapaat asiasanatlaserspektroskopia


Liittyvät organisaatiot

JYU-yksiköt:


OKM-raportointiKyllä

VIRTA-lähetysvuosi2023


Viimeisin päivitys 2024-12-10 klo 17:30