B3 Vertaisarvioimaton artikkeli konferenssijulkaisussa
Benchmark evaluation of a single frequency continuous wave OPO seeded pulsed dye amplifier for high-resolution laser spectroscopy (2023)
Urquiza-González, M., Au, M., Bernerd, C., Bissell, M. L., van den Borne, B., Chrysalidis, K., Cocolios, T. E., Fedosseev, V., Flanagan, K. T., Garcia Ruiz, R. F., Geldhof, S., de Groote, R. P., Koszorús, Á., Hanstorp, D., Heines, M., Heinke, R., Hens, K., Khwairakpam, O. S., Kujanpää, S., . . . Yang, X. F. (2023). Benchmark evaluation of a single frequency continuous wave OPO seeded pulsed dye amplifier for high-resolution laser spectroscopy. In W. A. Clarkson, & R. K. Shori (Eds.), Solid State Lasers XXXII : Technology and Devices (Article 123990M). SPIE. Proceedings of SPIE : the International Society for Optical Engineering, 12399. https://doi.org/10.1117/12.2646665
JYU-tekijät tai -toimittajat
Julkaisun tiedot
Julkaisun kaikki tekijät tai toimittajat: Urquiza-González, M.; Au, M.; Bernerd, C.; Bissell, M. L.; van den Borne, B.; Chrysalidis, K.; Cocolios, Thomas E.; Fedosseev, V.; Flanagan, K. T.; Garcia Ruiz, R. F.; et al.
Emojulkaisu: Solid State Lasers XXXII : Technology and Devices
Emojulkaisun toimittajat: Clarkson, W. Andrew; Shori, Ramesh K.
Konferenssin paikka ja aika: San Francisco, United States, 31.1.-1.2.2023
ISBN: 978-1-5106-5903-2
eISBN: 978-1-5106-5904-9
Lehti tai sarja: Proceedings of SPIE : the International Society for Optical Engineering
ISSN: 0277-786X
eISSN: 1996-756X
Julkaisuvuosi: 2023
Ilmestymispäivä: 08.03.2023
Sarjan numero: 12399
Artikkelinumero: 123990M
Kustantaja: SPIE
Julkaisumaa: Yhdysvallat (USA)
Julkaisun kieli: englanti
DOI: https://doi.org/10.1117/12.2646665
Julkaisun avoin saatavuus: Ei avoin
Julkaisukanavan avoin saatavuus:
Tiivistelmä
The study of the atomic spectrum via resonant laser excitation provides access to underlying effects caused by the nuclear structure, which is of special interest in short-lived radioisotopes produced at Isotope Separator On-Line (ISOL) facilities. Current implementations of resonant laser ionization techniques often limit the extraction of the nuclear observables due to the low spectral resolution of the pulsed laser systems deployed. Several high-resolution spectroscopy techniques demand spectral widths in the order of hundreds of MHz and below. A proven solution to reduce this linewidth is the pulsed amplification of a narrow-band continuous wave (cw) laser. This work presents the demonstration of a pulsed dye amplifier seeded by a commercially available cw Optical Parametric Oscillator (OPO). The performance of this system was compared with competing setups using a cw dye laser seed source as well as a frequency mixing technique using a combination of an injection-locked titanium:sapphire (Ti:Sa) and a Nd:YVO4 laser. Spectral bandwidths of the systems were measured using a high finesse Fabry-Perot Interferometer, resulting in comparable optical linewidths between 140 to 156 MHz at a wavelength of 328 nm for the different laser setups. Suitability for on-line experiments was validated by performing high-resolution spectroscopy of radioactive silver isotopes in the Collinear Resonance Ionization Spectroscopy (CRIS) experiment at the Isotope Separator On-Line Device (ISOLDE), at the European Organization for Nuclear Research (CERN). The quality of the hyperfine spectra was similar for the dye and the OPO seed and the deduced hyperfine splitting was in good agreement with literature, while the frequency mixing technique exhibited less precise results attributed to the frequency instabilities and mode-hops of the single-mode Nd:YVO4 laser.
YSO-asiasanat: lasertekniikka; spektroskopia; ydinfysiikka
Vapaat asiasanat: laserspektroskopia
Liittyvät organisaatiot
OKM-raportointi: Kyllä
VIRTA-lähetysvuosi: 2023