A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä
Reliability and concurrent validity of spatiotemporal stride characteristics measured with an ankle-worn sensor among older individuals (2019)


Rantalainen, T., Pirkola, H., Karavirta, L., Rantanen, T., & Linnamo, V. (2019). Reliability and concurrent validity of spatiotemporal stride characteristics measured with an ankle-worn sensor among older individuals. Gait and Posture, 74, 33-39. https://doi.org/10.1016/j.gaitpost.2019.08.006


JYU-tekijät tai -toimittajat


Julkaisun tiedot

Julkaisun kaikki tekijät tai toimittajatRantalainen, T.; Pirkola, H.; Karavirta, L.; Rantanen, T.; Linnamo, V.

Lehti tai sarjaGait and Posture

ISSN0966-6362

eISSN1879-2219

Julkaisuvuosi2019

Volyymi74

Artikkelin sivunumerot33-39

KustantajaElsevier

JulkaisumaaAlankomaat

Julkaisun kielienglanti

DOIhttps://doi.org/10.1016/j.gaitpost.2019.08.006

Julkaisun avoin saatavuusEi avoin

Julkaisukanavan avoin saatavuus

Julkaisu on rinnakkaistallennettu (JYX)https://jyx.jyu.fi/handle/123456789/66026


Tiivistelmä

Background. Wearable inertial sensors have been shown to provide valid mean gait characteristics assessments, however, assessment of variability is less convincingly established.

Research question. What level of concurrent validity, and session-to-session reliability does an ankle-worn inertial measurement unit (IMU)-based gait assessment with a novel angular velocity-based gait event detection algorithm have among older adults?

Methods. Twenty seven (women N = 17) participants volunteered (age 74.4 (SD 4.3) years, body mass 74.5 (12.0) kg, height 165.9 (9.9) cm). Right leg stance, swing, and stride duration and stride length, and stride velocity were concurrently assessed with motion capture and with an IMU from a 3 min self-paced walk up and back a 14 m track repeated twice a week apart. Gait variability was assessed as the SD of all of the registered strides.

Results. Significant difference was observed between methods for many of the mean stride characteristics and stride variability (all p < 0.05), fair to excellent agreement was observed for mean values of all of the five stride characteristics evaluated (intra-class correlation coefficient [ICC] from 0.43 to 1.00). However, poor agreement was observed for the SD of all of the evaluated stride characteristics (ICC from -0.25 to 0.00). Both methods indicated excellent session to session reliability for all of the five stride characteristics evaluated (ICC from 0.84 to 0.98, CV%RMS from 1.6% to 3.6%), whereas the variability characteristics exhibited poor to good reliability (ICC from 0.0 to 0.69, CV%RMS from 18.0% to 34.4%).

Significance. Excellent concurrent validity and reliability was observed for mean spatiotemporal stride characteristics, however, gait variability exhibited poor concurrent validity and reliability. Although IMUs and the presented algorithm could be used to assess mean spatiotemporal stride characteristics among older individuals, either a more reliable gait event detection algorithm or alternative analytical approaches should be used for gait variability.


YSO-asiasanatliikkeentunnistuskiihtyvyyskävelyikääntyneet

Vapaat asiasanatwearable; gait; accelerometer; motion capture; variability


Liittyvät organisaatiot


Hankkeet, joissa julkaisu on tehty


OKM-raportointiKyllä

Raportointivuosi2019

JUFO-taso1


Viimeisin päivitys 2024-08-01 klo 15:22