A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä
Validity and Reliability of a Single Question for Leisure-Time Physical Activity Assessment in Middle-Aged Women (2020)


Hyvärinen, Matti; Sipilä, Sarianna; Kulmala, Janne; Hakonen, Harto; Tammelin, Tuija H.; Kujala, Urho M.; Kovanen, Vuokko; Laakkonen, Eija K. (2020). Validity and Reliability of a Single Question for Leisure-Time Physical Activity Assessment in Middle-Aged Women. Journal of Aging and Physical Activity, 28 (2), 231-241. DOI: 10.1123/japa.2019-0093


JYU-tekijät tai -toimittajat


Julkaisun tiedot

Julkaisun kaikki tekijät tai toimittajat: Hyvärinen, Matti; Sipilä, Sarianna; Kulmala, Janne; Hakonen, Harto; Tammelin, Tuija H.; Kujala, Urho M.; Kovanen, Vuokko; Laakkonen, Eija K.

Lehti tai sarja: Journal of Aging and Physical Activity

ISSN: 1063-8652

eISSN: 1543-267X

Julkaisuvuosi: 2020

Volyymi: 28

Lehden numero: 2

Artikkelin sivunumerot: 231-241

Kustantaja: Human Kinetics, Inc.

Julkaisumaa: Yhdysvallat (USA)

Julkaisun kieli: englanti

DOI: http://doi.org/10.1123/japa.2019-0093

Avoin saatavuus: Julkaisukanava ei ole avoin

Julkaisu on rinnakkaistallennettu (JYX): https://jyx.jyu.fi/handle/123456789/66127


Tiivistelmä

Purpose: To investigate the validity and test–retest reliability of a single seven-level scale physical activity assessment question (SR-PA L7) and its three-level categorization (SR-PA C3).
Methods: The associations of SR-PA L7 and C3 with accelerometer-measured leisure-time physical activity (ACC-LTPA) and with the results of four different physical performance tests (6-min walk [n = 733], knee extension [n = 695], vertical jump [n = 731], and grip force [n = 780]) were investigated among women aged 47–55 years participating in the Estrogenic Regulation of Muscle Apoptosis study (n = 795). The reliability was studied using Spearman correlations with 4-month test–retest period (n = 152).
Results: SR-PA L7 and C3 had low correlations with ACC-LTPA (rs = .105–.337). SR-PA L7, SR-PA C3, and ACC-LTPA explained comparable but small amount of variance of the physical performance test results. The reliability analysis provided moderate agreement (rs = .707 and .622 for SR-PA L7 and C3, respectively).
Conclusions: SR-PA L7 and C3 demonstrated limited validity and reasonable repeatability.


YSO-asiasanat: fyysinen aktiivisuus; testaus; luotettavuus

Vapaat asiasanat: accelerometry; physical activity measurement; self-reported physical activity; test–retest reliability


Liittyvät organisaatiot


Hankkeet, joissa julkaisu on tehty


OKM-raportointi: Kyllä

Raportointivuosi: 2020

Alustava JUFO-taso: 1


Viimeisin päivitys 2020-18-08 klo 13:02