B3 Non-refereed conference proceedings
Central region upgrade for the Jyväskylä K130 cyclotron (2020)


Kalvas, T.; Heikkinen, P.; Koivisto, H.; Forton, E.; Kleeven, W.; Mandrillon, J.; Nuttens, V. (2020). Central region upgrade for the Jyväskylä K130 cyclotron. In Conradie, Lowry; De Villiers, Garrett; Schaa, Volker RW (Eds.) Cyclotrons 2019 : Proceedings of the 22nd International Conference on Cyclotrons and their Applications (CYC 2019). JACoW Publishing, 327-330. DOI: 10.18429/JACoW-Cyclotrons2019-THD02 https://cyclotrons2019.vrws.de/papers/proceed.pdf


JYU authors or editors


Publication details

All authors or editors: Kalvas, T.; Heikkinen, P.; Koivisto, H.; Forton, E.; Kleeven, W.; Mandrillon, J.; Nuttens, V.

Parent publication: Cyclotrons 2019 : Proceedings of the 22nd International Conference on Cyclotrons and their Applications (CYC 2019)

Parent publication editors: Conradie, Lowry; De Villiers, Garrett; Schaa, Volker RW

Conference:

International Conference on Cyclotrons and their Applications

Place and date of conference: Cape Town, South Africa, 22.-27.9.2019

ISBN: 978-3-95450-205-9

Publication year: 2020

Pages range: 327-330

Number of pages in the book: 388

Publisher: JACoW Publishing

Publication country: South Africa

Publication language: English

DOI: http://doi.org/10.18429/JACoW-Cyclotrons2019-THD02

Persistent website address: https://cyclotrons2019.vrws.de/papers/proceed.pdf

Open Access: Publication published in an open access channel

Publication is parallel published (JYX): https://jyx.jyu.fi/handle/123456789/71020


Abstract

The Jyväskylä K130 cyclotron has been in operation for more than 25 years providing beams from H to Au with energies ranging from 1 to 80 MeV/u for nuclear physics research and applications. At the typical energies around 5 MeV/u used for the nuclear physics program the injection voltage used is about 10 kV. The low voltage limits the beam intensity especially from the 18 GHz ECRIS HIISI. To increase the beam intensities the central region of the K130 cyclotron is being upgraded by increasing the injection voltage by a factor of 2. The new central region with spiral inflectors for harmonics 1-3 has been designed. The new central region shows better transmission in simulations than the original one for all harmonics and especially for h=2 typically used for nuclear physics. The engineering design for the new central region is being done.


Keywords: cyclotrons; particle accelerators; ions


Contributing organizations


Ministry reporting: Yes

Reporting Year: 2020