A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä
Students’ school‐level symptoms mediate the relationship between a school’s observed moisture problems and students’ subjective perceptions of indoor air quality (2021)


Finell, E., Tolvanen, A., Ikonen, R., Pekkanen, J., & Ståhl, T. (2021). Students’ school‐level symptoms mediate the relationship between a school’s observed moisture problems and students’ subjective perceptions of indoor air quality. Indoor Air, 31(1), 40-50. https://doi.org/10.1111/ina.12711


JYU-tekijät tai -toimittajat


Julkaisun tiedot

Julkaisun kaikki tekijät tai toimittajatFinell, Eerika; Tolvanen, Asko; Ikonen, Riikka; Pekkanen, Juha; Ståhl, Timo

Lehti tai sarjaIndoor Air

ISSN0905-6947

eISSN1600-0668

Julkaisuvuosi2021

Ilmestymispäivä03.07.2020

Volyymi31

Lehden numero1

Artikkelin sivunumerot40-50

KustantajaWiley-Blackwell

JulkaisumaaYhdysvallat (USA)

Julkaisun kielienglanti

DOIhttps://doi.org/10.1111/ina.12711

Julkaisun avoin saatavuusAvoimesti saatavilla

Julkaisukanavan avoin saatavuusOsittain avoin julkaisukanava

Julkaisu on rinnakkaistallennettu (JYX)https://jyx.jyu.fi/handle/123456789/71095


Tiivistelmä

Moisture damage can influence the subjective assessment of indoor air quality (subjective IAQ) in various ways. We studied whether the frequency of symptoms reported across students at school level mediates the relationship between observed mold and dampness in a school building and students’ subjective IAQ. To answer this research question, we tested a multilevel path model.

The analyzed data was created by merging two nationwide data sets: 1) survey data from students, including information on subjective IAQ (N = 24,786 students); 2) data from schools, including information on mold and dampness in a school building (N = 222).

After the background variables were adjusted, schools’ observed mold and dampness was directly and significantly related to poor subjective IAQ (standardized beta (β)= 0.22, p = 0.002). In addition, in schools with mold and dampness, students reported significantly more symptoms (β = 0.22, p = 0.023) than in schools without; the higher the prevalence of symptoms at school level, the worse the students’ subjective IAQ (β = 0.60, p < 0.001). This indirect path was significant (p = 0.023). In total, schools’ observed mold and dampness and student‐reported symptoms explained 52 % of the between‐school variance in subjective IAQ.


YSO-asiasanatkosteushomesisäilmailmanlaatukoulutsairas rakennus -oireyhtymäoppilaatoireet

Vapaat asiasanatdampness; indoor air quality; indoor environmental problems; multilevel analysis; school; symptoms


Liittyvät organisaatiot

JYU-yksiköt:


OKM-raportointiKyllä

VIRTA-lähetysvuosi2021

JUFO-taso2


Viimeisin päivitys 2024-12-10 klo 08:45