Calibration strategy of the JUNO experiment (2021)


JUNO collaboration. (2021). Calibration strategy of the JUNO experiment. Journal of High Energy Physics, 2021(3), Article 4. https://doi.org/10.1007/jhep03(2021)004


JYU authors or editors


Publication details

All authors or editors: JUNO collaboration

Journal or series: Journal of High Energy Physics

ISSN: 1126-6708

eISSN: 1029-8479

Publication year: 2021

Volume: 2021

Issue number: 3

Article number: 4

Publisher: Springer Science and Business Media LLC

Publication country: Germany

Publication language: English

DOI: https://doi.org/10.1007/jhep03(2021)004

Publication open access: Openly available

Publication channel open access: Open Access channel

Publication is parallel published (JYX): https://jyx.jyu.fi/handle/123456789/74526

Publication is parallel published: https://arxiv.org/abs/2011.06405


Abstract

We present the calibration strategy for the 20 kton liquid scintillator central detector of the Jiangmen Underground Neutrino Observatory (JUNO). By utilizing a comprehensive multiple-source and multiple-positional calibration program, in combination with a novel dual calorimetry technique exploiting two independent photosensors and readout systems, we demonstrate that the JUNO central detector can achieve a better than 1% energy linearity and a 3% effective energy resolution, required by the neutrino mass ordering determination.


Keywords: physics; neutrinos; calibration


Contributing organizations


Ministry reporting: Yes

Reporting Year: 2021

JUFO rating: 2