Properties of Gd-Doped Sol-Gel Silica Glass Radioluminescence under Electron Beams (2022)


Söderström, D., Timonen, O., Kettunen, H., Kronholm, R., El Hamzaoui, H., Capoen, B., Ouerdane, Y., Morana, A., Javanainen, A., Bouwmans, G., Bouazaoui, M., & Girard, S. (2022). Properties of Gd-Doped Sol-Gel Silica Glass Radioluminescence under Electron Beams. Sensors, 22(23), Article 9248. https://doi.org/10.3390/s22239248


JYU-tekijät tai -toimittajat


Julkaisun tiedot

Julkaisun kaikki tekijät tai toimittajatSöderström, Daniel; Timonen, Oskari; Kettunen, Heikki; Kronholm, Risto; El Hamzaoui, Hicham; Capoen, Bruno; Ouerdane, Youcef; Morana, Adriana; Javanainen, Arto; Bouwmans, Géraud; et al.

Lehti tai sarjaSensors

eISSN1424-8220

Julkaisuvuosi2022

Ilmestymispäivä28.11.2022

Volyymi22

Lehden numero23

Artikkelinumero9248

KustantajaMDPI

JulkaisumaaSveitsi

Julkaisun kielienglanti

DOIhttps://doi.org/10.3390/s22239248

Julkaisun avoin saatavuusAvoimesti saatavilla

Julkaisukanavan avoin saatavuusKokonaan avoin julkaisukanava

Julkaisu on rinnakkaistallennettu (JYX)https://jyx.jyu.fi/handle/123456789/84204


Tiivistelmä

The radiation-induced emission (RIE) of Gd3+-doped sol–gel silica glass has been shown to have suitable properties for use in the dosimetry of beams of ionizing radiation in applications such as radiotherapy. Linear electron accelerators are commonly used as clinical radiotherapy beams, and in this paper, the RIE properties were investigated under electron irradiation. A monochromator setup was used to investigate the light properties in selected narrow wavelength regions, and a spectrometer setup was used to measure the optical emission spectra in various test configurations. The RIE output as a function of depth in acrylic was measured and compared with a reference dosimeter system for various electron energies, since the dose–depth measuring abilities of dosimeters in radiotherapy is of key interest. The intensity of the main radiation-induced luminescence (RIL) of the Gd3+-ions at 314 nm was found to well represent the dose as a function of depth, and was possible to separate from the Cherenkov light that was also induced in the measurement setup. After an initial suppression of the luminescence following the electron bunch, which is ascribed to a transient radiation-induced attenuation from self-trapped excitons (STEX), the 314 nm component was found to have a decay time of approximately 1.3 ms. An additional luminescence was also observed in the region 400 nm to 600 nm originating from the decay of the STEX centers, likely exhibiting an increasing luminescence with a dose history in the tested sample.


YSO-asiasanatdosimetritoptiset kuidutvaimennusluminesenssi

Vapaat asiasanatdosimetry; electron accelerator; optical fiber; point dosimeter; pulsed electron beam; radiation-induced attenuation; radiation-induced luminescence